The Most Fuel-Efficient 50kVA Diesel Generator

by | Aug 19, 2024 | Fuel Efficiency, Generator, Knowledge Base, Tips & Guides

The Most Fuel-Efficient 50kVA Diesel Generator

Fuel consumption can make a significant difference to the real cost of owning and operating a 50kVA diesel generator, particularly when the generator is being used for prime power and running for hundreds or thousands of hours each year.

At Target Power Generators, we supply and work with a range of 50kVA generators using engines from Perkins, Caterpillar, Baudouin, Cummins and other major manufacturers. This gives us a good opportunity to compare the figures rather than simply looking at one brand.

So, which 50kVA diesel generator uses the least fuel?

Based on the comparable figures we have available, the Perkins 1103A-33TG1 remains one of the strongest options in this power range, consuming approximately 8.2 litres per hour at 75% load.

It is also the engine we use in our Ferbo FE50-P Prime Advanced generator, combining the Perkins engine with a Mecc Alte alternator and a generator package designed for regular prime-power applications.

Contents

50kVA Diesel Generator Fuel Consumption Comparison

The table below compares fuel consumption figures for several engines commonly found around the 50kVA generator power range.

It is important to remember that generator ratings and manufacturer test conditions can differ slightly, so figures should be treated as a useful comparison rather than assuming every generator has been tested under completely identical conditions.

Generator / Engine Engine 50% Load 75% Load 100% Load
Ferbo FE50-P Perkins 1103A-33TG1 Approx. 5.7 L/h 8.2 L/h Approx. 10.7 L/h
CAT 50kVA Class CAT C3.3 Approx. 6.0 L/h Approx. 8.7 L/h Approx. 11.7 L/h
Ferbo 50kVA Class Baudouin 4M06 Approx. 6.0 L/h Approx. 8.9 L/h Approx. 11.9 L/h
Cummins 50kVA Class Cummins 4BTA3.9-G2 Approx. 7.9 L/h Approx. 11.9 L/h Approx. 15.9 L/h

Figures are based on manufacturer data available to us and may vary according to generator specification, operating conditions, temperature, altitude and actual electrical load.

Which 50kVA Diesel Generator Is the Most Fuel Efficient?

Looking at the figures above, the Perkins 1103A-33TG1 performs particularly well in the 50kVA class.

At approximately 75% load, it consumes around 8.2 litres of diesel per hour.

That compares with approximately 8.7 L/h for the CAT C3.3, 8.9 L/h for the Baudouin option and 11.9 L/h for the Cummins 4BTA3.9-G2 in the figures available to us.

For a standby generator that only operates occasionally, the difference may not amount to very much over the life of the machine.

For a generator running every day, it can be a completely different story.

Why Is the Perkins 1103A-33TG1 a Good 50kVA Generator Engine?

The Perkins 1103A-33TG1 is a 3.3-litre, three-cylinder industrial diesel engine operating at 1500rpm in a 50Hz generator application.

One of its strengths is that it can produce the required output without using an unnecessarily large engine for this power node.

Its fuel consumption figures are approximately:

  • 50% load: 5.7 litres per hour
  • 75% load: 8.2 litres per hour
  • 100% prime load: 10.7 litres per hour

Fuel economy is not the only reason we like this engine.

Perkins is an established industrial engine manufacturer, and the 1103 platform is widely used in power-generation equipment. For UK customers, the availability of service knowledge and genuine replacement parts is another significant advantage.

For a generator expected to accumulate substantial running hours, we think that combination of fuel economy, simplicity, parts availability and support makes a lot of sense.

How Much Does a 50kVA Diesel Generator Cost to Run?

The easiest way to understand why fuel efficiency matters is to turn litres per hour into an annual fuel requirement.

Using the Perkins figure of 8.2 L/h at 75% load:

Operating Hours Approx. Diesel Used
100 hours 820 litres
500 hours 4,100 litres
1,000 hours 8,200 litres
2,000 hours 16,400 litres

If you know your delivered diesel price, you can multiply it by these figures to estimate the fuel element of your running costs.

This also demonstrates why relatively small differences in litres per hour matter on a prime-running generator.

For example, comparing 8.2 L/h with 11.9 L/h gives a difference of 3.7 litres every operating hour.

Over 1,000 hours, that represents approximately 3,700 litres of diesel.

That is why we recommend looking beyond the initial purchase price when comparing generators that will be used regularly.

Why Generator Load Makes Such a Difference

A diesel generator does not consume the same amount of fuel regardless of how much electricity you are using.

As electrical load increases, fuel consumption increases.

This is why simply asking, “How much fuel does a 50kVA generator use per hour?” does not have one accurate answer.

You need to know the actual load.

A 50kVA generator running at 50% load will use considerably less diesel per hour than the same generator at 100% load.

Correct generator sizing therefore matters. Buying a generator considerably larger than the actual requirement can mean spending more on the generator itself while operating the diesel engine at an unnecessarily low load.

For many variable-load prime-power applications, operating within a sensible working load range is preferable to continually running a substantially oversized generator.

Ferbo FE50-P Prime Advanced – Our 50kVA Perkins Generator

For customers looking for a premium 50kVA-class generator for regular operation, one of the machines we now specify is the Ferbo FE50-P Prime Advanced.

The current FE50-P specification combines:

  • Perkins 1103A-33TG1 diesel engine
  • Mecc Alte alternator
  • 1500rpm, 50Hz operation
  • Approximately 8.2 L/h fuel consumption at 75% load
  • Automatic generator control
  • Acoustic weatherproof canopy
  • Compact industrial construction
  • Prime-power focused specification

For us, this is an important distinction.

A fuel-efficient engine is useful, but we still need the rest of the generator to be right.

The alternator, control system, electrical protection, fuel system, acoustic enclosure, cooling system and service access all contribute to whether a generator is actually suitable for regular operation.

You can browse our Ferbo Prime Advanced generators here.

The Most Fuel-Efficient Generator Isn’t Automatically the Best Generator

We think fuel consumption should be an important part of choosing a generator, but it should not be the only consideration.

Two generators can use similar amounts of diesel while being very different machines.

We would also compare:

  • Prime and standby power ratings
  • Engine manufacturer and parts support
  • Alternator quality
  • Control module
  • Main circuit breaker and electrical protection
  • Fuel tank capacity
  • Bunded or retention base
  • External bulk fuel connections
  • Noise level
  • Canopy construction
  • Corrosion protection
  • Service access
  • Warranty
  • UK parts and technical support

We go into these points in much more detail in our guide to what makes a premium diesel generator.

Prime Power vs Standby Power

How you intend to use the generator should also influence how much importance you place on fuel economy.

Standby Power

If a 50kVA generator is installed purely for emergency backup and only operates for a relatively small number of hours each year, fuel consumption may be less important than reliability, automatic starting and the complete standby specification.

Prime Power

If the generator is your main source of electricity and runs for hundreds or thousands of hours, fuel consumption becomes much more important.

A saving of even one or two litres per hour can become substantial over the working life of the generator.

This is one reason our Ferbo Prime Advanced range is configured specifically around customers who intend to work their generators rather than simply leave them waiting for a mains failure.

Which 50kVA Generator Should You Buy?

If fuel economy is one of your main priorities, the Perkins 1103A-33TG1 remains a very strong engine choice in the 50kVA power class based on the figures available to us.

At around 8.2 litres per hour at 75% load, it compares favourably with several other popular industrial engines in this power range.

That is why we continue to offer the Perkins engine in our Ferbo FE50-P Prime Advanced generator.

However, we would always recommend sizing the generator around the application rather than choosing purely from a fuel-consumption table.

If your actual requirement is closer to 30kVA, buying a 50kVA machine purely because it has an efficient engine may still leave you with an oversized generator.

For smaller applications, read our most fuel-efficient 30kVA diesel generator comparison.

Can We Compare Fuel Consumption for Your Application?

Yes. This is something we regularly do for customers.

If you tell us the expected electrical load, operating hours and application, we can compare suitable generator options rather than simply quoting the cheapest machine.

For a prime-running generator, we can also look at estimated annual diesel consumption. That can make the difference between two engine options much clearer than comparing purchase prices alone.

See Our Generators Running

We regularly test and film generators at our UK facility, including noise demonstrations, product walkarounds and generators prepared for customer projects.

Watch our Ferbo Generator Video Library on YouTube →

Looking for a Fuel-Efficient 50kVA Diesel Generator?

If you are looking for a 50kVA generator for prime power, agriculture, construction, industrial use or standby power, speak to Target Power Generators.

We can compare engine options, fuel consumption, noise levels and complete generator specifications to help you choose the right machine for the application.

We keep industrial diesel generators physically in stock in the UK for fast delivery.

Contact Target Power Generators →

Read more

Proud to be 5 star rated

Need help? Get in touch

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.