Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Select Page

Backed by expert advice

Fast UK delivery

Global shipping

500kVA Scania Generator for Recycling Plant In Widnes

by | Sep 17, 2026 | Case Studies, Recycling

500kVA Scania Diesel Generator for Recycling Facility in Widnes – Fresco Environmental

When a diesel generator is going to be used as the main source of power rather than simply sitting there for emergency standby, the specification becomes much more important.

Fuel consumption, noise, fuel capacity, serviceability and reliability all have a direct effect on the customer’s day-to-day operating costs.

This was exactly the case for Fresco Environmental, a recycling company requiring a large industrial diesel generator to power machinery and equipment at its site in Widnes.

We supplied a 500kVA prime / 550kVA standby Ferbo diesel generator powered by a Scania DC13 engine, together with a 2,000-litre external fuel tank.

From order to delivery in Widnes, we turned the complete project around in just two working days. We are also providing the ongoing generator servicing and maintenance, giving the customer continued support after installation.

Contents

What Generator Did Fresco Environmental Require?

The customer needed a generator capable of supplying machinery and processing equipment across the recycling site.

This was not an occasional emergency-backup application. The generator was going to be used for prime power, meaning it could be operating for long periods and accumulating substantial running hours.

After looking at the requirement, we supplied a Ferbo Scania-powered generator providing:

  • 500kVA prime power
  • 550kVA standby power
  • 400-415V three-phase output
  • Scania DC13 diesel engine
  • Low-noise acoustic canopy
  • 850-litre internal fuel tank
  • External bulk fuel feed and return connections
  • Industrial control and circuit protection

You can view our 500kVA Scania-powered Ferbo generator range here, or browse all of our 500kVA diesel generators.

Why a Scania-Powered Generator?

One of the main reasons this generator suited the application was the Scania DC13 diesel engine.

At this power node, we particularly like the Scania because it combines strong industrial performance with very competitive fuel consumption.

When a generator is only being used for standby, a few litres per hour difference in fuel consumption may not make a huge difference over the year.

When that same generator is being used as the site’s main source of power, it is completely different.

A prime-running 500kVA generator can operate for thousands of hours, so even relatively small differences in fuel consumption can turn into thousands of pounds in operating costs.

This is why we do not simply choose the cheapest engine available at each power node. We look at the initial purchase price, but also what the generator is likely to cost the customer to run.

Why Fuel Efficiency Matters at 500kVA

A 500kVA generator is consuming a substantial amount of diesel when operating under load, so fuel efficiency was particularly important for this application.

If one engine uses only a few litres per hour less than another, the saving becomes significant surprisingly quickly.

For example, a difference of just 4 litres per hour would represent:

  • 400 litres over 100 operating hours
  • 4,000 litres over 1,000 operating hours
  • 20,000 litres over 5,000 operating hours

That is before putting an actual diesel price against the saving.

For a recycling plant, quarry, factory, farm or other industrial site running from generator power, fuel consumption therefore needs to be considered as part of the purchase decision rather than after the generator has arrived.

This is the same approach we discuss in our guide to what makes a premium diesel generator.

Low-Noise Power for an Industrial Site

The customer also wanted a generator with strong acoustic performance.

Large generators do not have to be excessively noisy.

The Ferbo Scania package uses a purpose-designed sound-attenuated canopy, with the complete enclosure, cooling airflow, exhaust system and engine installation designed together.

Our Scania-powered Ferbo generators at this output are among the quieter large industrial generator packages we supply, with published sound levels around the high-60 dBA range at 7 metres depending on the exact model and test conditions.

That can make a considerable difference on sites where people are working nearby or where the surrounding area includes other businesses or residential properties.

We explain why the canopy makes such a difference in our Generator Canopy Designs Explained guide.

850-Litre Internal Tank Plus 2,000-Litre External Fuel Tank

For a generator being used for prime power, fuel capacity becomes just as important as fuel consumption.

The generator supplied was configured with a large 850-litre internal fuel tank together with external bulk fuel feed and return connections.

We then supplied a separate 2,000-litre diesel fuel tank to substantially increase the available fuel capacity on site.

This is one of the features we particularly like about our larger Ferbo prime-power generators.

The external fuel connections make it straightforward to connect a suitable bulk tank, giving the customer far greater flexibility for continuous operation.

The operator can use the generator’s internal tank or connect the external bulk supply depending on how the generator is being operated.

For a site running for extended periods, this reduces the need to repeatedly stop and refill the generator’s internal tank.

We stock a range of bulk diesel fuel tanks for generator applications, including approximately 1,000, 2,000, 3,000-litre and larger options.

Designed for Prime Running

This is also a good example of why we separate our Ferbo specifications according to how the generator will actually be used.

A generator that sits outside a building waiting for a mains failure needs a different specification from a machine expected to power industrial equipment every working day.

For prime-running applications we place much more emphasis on:

  • Fuel efficiency
  • Large fuel capacity
  • External bulk fuel connections
  • Six-way fuel systems where specified
  • Low-noise acoustic performance
  • Corrosion protection
  • Service access
  • Heavy-duty construction
  • Reliable industrial engines and alternators

This philosophy forms the basis of our Ferbo Prime Advanced diesel generator range.

You can also read more about why we selected Ferbo as one of our core industrial generator ranges in our guide: Why Choose Ferbo Generators?

From Stock to Widnes in Two Working Days

Specification was only one part of this project. The customer also needed the generator quickly.

Because we physically held the 500kVA generator in stock, we were able to organise the complete package and have the project turned around within two working days.

We coordinated HIAB delivery to the customer’s recycling facility in Widnes, allowing the generator to be safely unloaded and positioned on site.

For a generator of this size, delivery needs to be considered at the start of the project rather than when the lorry arrives at the gate. Access, lifting points, offloading equipment and final positioning all form part of getting a large industrial generator onto site successfully.

This is one of the reasons we maintain strong physical stock levels rather than relying entirely on factory lead times.

Customers can view our current diesel generator stock for machines available for fast UK delivery and worldwide export.

Ongoing Generator Service & Maintenance

Our involvement with the project did not finish when the generator arrived in Widnes.

Because this is a prime-running generator, regular servicing is particularly important. The engine can accumulate hours quickly, so filters, oils, coolant, belts and other service items need to be inspected and replaced at the correct intervals.

We are therefore also providing Fresco Environmental with an ongoing generator service and maintenance contract.

This gives us the opportunity to support the generator throughout its working life, rather than simply supplying the machine and leaving the customer to look after it.

For a prime-power application, we think this is particularly important. Preventative maintenance helps reduce the risk of unexpected downtime, while also allowing service requirements to be planned around the customer’s operation.

We can provide servicing, maintenance, genuine service parts and technical support for industrial diesel generators throughout the UK.

A Complete Generator, Fuel & Service Package

Rather than simply selling Fresco Environmental a 500kVA generator, the final solution included:

  • 500kVA prime / 550kVA standby Ferbo generator
  • Scania DC13 diesel engine
  • Low-noise acoustic enclosure
  • 850-litre internal fuel tank
  • External bulk fuel feed and return system
  • 2,000-litre external diesel fuel tank
  • HIAB delivery and offload in Widnes
  • Ongoing generator servicing and maintenance contract

From receiving the order to delivering the complete generator and fuel package, the project was turned around within two working days.

For us, that is what supplying industrial power should be about: not simply providing a generator, but looking at the fuel system, delivery, ongoing running costs and maintenance requirements as one complete package.

Where Else Would a 500kVA Generator Be Used?

500kVA is a popular industrial power node because it can support substantial electrical loads while remaining available in a conventional canopied generator package.

Typical applications include:

  • Recycling and waste-processing plants
  • Quarries and mineral processing
  • Manufacturing facilities
  • Agriculture and large farms
  • Food production
  • Construction projects
  • Industrial prime power
  • Large commercial standby systems
  • Events and temporary power
  • Remote and off-grid industrial sites

For applications requiring even longer runtime, our generator systems can also be configured with larger bulk tanks and bespoke fuel-management systems.

See Our Ferbo Generators in Action

We regularly film our Ferbo generators, including large industrial sets, product walkarounds, running demonstrations, noise tests and customer machines.

Watch our Ferbo Generator Video Library on YouTube →

Need an Industrial Prime-Power Generator?

If your business needs a diesel generator to operate machinery, processing equipment or an entire industrial site, speak to our technical team before simply selecting a kVA rating.

We can help with the electrical load, operating hours, motor starting requirements, fuel consumption, noise, bulk fuel storage, delivery and ongoing servicing to build a complete solution around the application.

With generators physically in stock, bulk fuel tanks available and nationwide delivery and maintenance support, we can provide the complete package from initial sizing through to ongoing servicing.

Speak to Target Power about your industrial generator requirement →

Read more

Proud to be 5 star rated

Need help? Get in touch

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.